Concrete mixing plant should be how to solve the gas supply fails

2013-11-21

Concrete mixing plant air mixing equipment company failures are most often encountered problems, but how to solve it stumped a lot of people . Zhengzhou Bona company based on years of production and sale of concrete mixing station technology and experience , summed up some of the gas mixing station and analyze the causes and resolution . I hope the new and old customers for concrete mixing station maintenance help.
Concrete mixing plant air supply failure and solutions are:
( A ) air compressor failures are: non-return valve is damaged, badly worn piston rings , inlet valve is damaged and air filter blockage.
To determine the concrete batching mixing plant check valve is damaged , just ten seconds after the compressor automatically shut down , turn off the power , the hand plate moving large belt wheel , if can more easily turn a week , then the only reverse valve is not damaged; Conversely , non-return valve is damaged; Further, automatic pressure switch from an exhaust port below the discharge conditions to be judged , in general , after the air compressor should be shut down automatically after about ten seconds stop the exhaust , if you have been in the exhaust until the compressor starts again when to stop , then the check valve is damaged, must be replaced .
When the pressure of the air compressor oil rises slowly and accompanied by string phenomenon that has been severely worn piston ring compressor , should be replaced.
When the intake valve is damaged or clogged air filter , but also make the air compressor pressure rises slowly ( but no strings oil phenomenon ) . Checking , can be put to the palm of the air inlet filter , if the heated air out the top , then place the intake valve is damaged , must be replaced ; if suction is small , usually caused by dirty air filters , filters should be cleaned or replaced .
( 2 ) concrete mixing station valve failure are: pressure regulator is not high, or the slow pressure rise . Pressure regulator is not high, often due to pressure regulator spring break or diaphragm failure and must be renewed ; pressure rises slowly , usually caused because the filter is clogged , should be removed and washed .
( 3 ) Piping failures are: leaking pipe joints , hose rupture, condensate aggregation .
Leaking pipe joints and hose rupture up to judge the sound leak from the site , should be promptly repaired or replaced ; if there is accumulating condensate pipeline , it shall promptly drained , is characterized by condensed water in the northern winter, easy to knot ice and clogging gas .
( 4 ) Dry mix concrete batch plant air handling component failures are: oil and water separator failure , regulator and lubricator failure.
Failure of oil-water separator is divided into , filter clogging , breakage , drain valve moving parts moving parts is not flexible and so on. Work should always clean the filter , remove sewage and impurities inside the oil .